What are Tubular Gel batteries?

What are the benefits of gel battery?

There are distinct advantages of lead-acid battery technology compared to lithium-ion battery & other electrochemical systems. Affordability, reliability, recyclability and safety are key issues in choosing the right battery for a particular application and lead-acid batteries will score highly in these categories. There is, however, a drawback when using conventional flooded lead-acid batteries for deep cycle applications. This is the maintenance required in topping up the batteries due to water loss by gassing. In many applications, like in traction battery applications, there is a need to completely recharge a battery in a limited time frame. This normally will require higher voltages which in turn leads to the breakdown and loss of water from the electrolyte through gassing. These lead-acid batteries will require topping up with water, creating inconvenience and costs and in large installations which often requires expensive extraction equipment. There are also other disadvantages, particularly with transport, storage and disposal. The liquid acid in the lead-acid battery is classified as a hazardous material for transport. Whilst this is not considered a problem within the industry, which operates using safe and proven procedures, it is much better to immobilise the acid to prevent spillages. One fortunate consequence of acid immobilisation is that it creates the ability to recombine the hydrogen and oxygen gases which are produced from the breakdown of water inside the battery when on charge. There are two principal methods for acid immobilisation:

  • the other, adding a fine silica powder to make a gel as in Gel Battery

Both methods, although very different, achieve the goal of immobilisation. They also provide the added benefit of recombining the gases released on charge to reform water, thereby removing the need for the water-addition maintenance procedures mentioned earlier for flooded lead-acid batteries. Out of these two methods, the use of silica-gelled electrolyte is universally recognised as the best solution for deep discharge gel cell battery designs. There are two main reasons for this: the first is that the use of gelled electrolyte allows a tubular positive plate to be used, which is recognised as providing the best deep cycle properties for lead-acid batteries. The second reason is that the stratification of acid associated with deep discharges and limited-voltage recharging without gassing is avoided. These are significant advantages if you have deep cycle requirements as in solar battery applications. The use of tubular plate batteries provides the most robust lead-acid battery design with the highest deep cycle capability of all lead-acid designs. The resistance to stratification is of great benefit in many applications which operate at partial state of charge (PSoC) such as standby power, UPS and Solar Energy clean environment markets.

​Gel Batteries: Advantages And Disadvantages

The main advantages of the gel battery is the absence of the need to top up your battery. So why is the lack of topping up, such an advantage? You have to consider the problems of maintaining lead-acid batteries in remote locations with difficult access. In flooded batteries, if you forget to top up with water they can dry out and fail. The cost of maintaining these batteries with regular monthly or quarterly visits can be very high. For a business, this can make an installation uneconomical. The other side of this expensive coin is the maintenance, particularly in commercial environments where equipment reliability is key to providing a reliable and regular service. If batteries powering essential equipment fail due to lack of maintenance, the ramifications for credibility and reputation can be considerable. For the private user, it can be equally frustrating. For example, having to access installed batteries and obtain distilled water sometimes is not so easy, not to mention keeping a log and records for possible warranty claims. And of course, there is the situation where we are simply extremely busy and accessing and maintaining batteries can be a really time draining exercise. 

There are also those clean environments where charging batteries can produce damaging or even explosive fumes, particularly in confined spaces. This is particularly relevant for batteries used in computer backup and medical equipment applications where batteries are kept in cabinets or inside complex and sensitive equipment. To remove fumes from charging batteries it is sometimes necessary to install expensive extraction equipment to remove explosive hydrogen gas and corrosive acid fumes from confined spaces in cabinets or equipment. There are also clean environment applications as in hospitals and food storage. In these environments smells and corrosive gases could contaminate food or damage human health. Looking again to the consumer applications, the last thing they need is a battery in their home, garage or solar power bank, which is producing explosive gases or corrosive fumes on when on charge. 

They are sealed batteries. Do not leak. There is no risk of acid leakages. They are maintenance-free. They are classified as non-hazardous for transportation, rail or air. Terminals do not have any corrosion.

There is no risk of leakages in a gel battery since the electrolyte is in gel form. Since they cannot leak the TGel battery can be placed in any orientation. If the battery falls or breaks there will be no spilt acid damage caused due to the accidental spillage of acid like from a wet cell battery. Gel batteries are designed to be resistant to vibration & shocks. They don’t release explosive gases like in large battery bank installations of flooded batteries. They recover faster from a deep discharge or if left discharged over a long time. They have a huge life span & comes maintenance free! 

The only disadvantage of a Tubular gel cell is the initial cost compared to to the flooded battery or the AGM battery. The gel batteries usually cost 30 to 40% more than the normal batteries. This cost though appears to be more, easily is offset by the Return on Investment as explained above. Other than the cost there are only advantages!

What is gel battery technology?

So just how do this combination of tubular plate and GEL electrolyte work? To understand we have to look at several elements which contribute to the battery’s properties, these are:

An electrolyte which is immobilized as a GEL to ensure non-spillage and also to enable the transportation of hydrogen and oxygen released on charging (which is held inside the battery under pressure) to be recombined to form water. The benefit of immobilization extends further, it prevents the creation of strata of acid with different densities within the cells, called Acid Stratification. In flooded batteries and sometimes AGM VRLA designs, denser gravity acid produced at the plates during charge can drop to the bottom of the cell leaving the weaker gravity acid at the top. Batteries in this condition suffer early failure from battery sulphation, premature capacity loss (PCL) and grid corrosion. Microtex have a Tubular gel plant imported from Germany and use high-grade imported fumed silica to give uncompromising life and performance to their Tgel cells.

Multi tubular gauntlets
Multi tubular gauntlets with different diameters & spines
Tubular Spine grid Golf Cart Battery
Tubular Battery Spine grid
Tubular Positive Plate
Tubular Positive Plate
800Ah OPzV Battery
2v 800Ah OPzV Cells
Lead Acid Battery Tubular Positive Plate Cross Section
Lead Acid Battery Tubular Positive Plate Cross Section
48v 800Ah OPzV Battery Bank
48v 800Ah OPzV Battery Bank

What are the differences between AGM and gel batteries?

Absorbent glass mat or AGM batteries use a glass mat like a sponge to retain the acid inside the cell. There is no free acid & is generally called a starved electrolyte condition battery. The AGM battery uses flat plates for the positive & the negative electrodes, which unlike tubular positive plates are more prone to corrosion. AGM batteries have a lesser life compared to Gel battery. 

TGEL battery uses tubular design of the battery plate. This is essentially a pressure cast lead alloy spine instead of a grid, which is covered by a fabric gauntlet then filled with the positive active material (PAM). This can be either a dry lead oxide powder or a wet lead oxide slurry. A tubular battery design of plate has a couple of advantages: the first is that it has a higher surface area in contact with acid to give better material utilization (as much as 60%). (As seen in the pic above). The second reason is that tubular battery and 2v cells have the highest cycle life of the entire lead acid battery range. Under standard deep cycle test conditions (80% depth of discharge), some 2v cells in tubular designs can achieve over 2,000 cycles before the capacity drops to 80% of its original value. The corrosion-resistant alloy used in the positive spine ensures the longest achievable life of any 2v gel VRLA battery on the market. Microtex makes their own lead alloys to ensure the highest quality and best specification for their 2v batteries. Using an optimized lead – calcium alloy with high tin content ensures that premature battery failures due to positive grid growth and spine corrosion are effectively prevented. This is not the cheapest material and self-manufactured not the most convenient way of obtaining the components for lead-acid batteries, but it does give the best form of control to meet the demanding quality standards for which Microtex batteries are renowned. Tailor-made lead calcium tin alloys used in the positive tubular plates and flat negative plates almost eliminate the hydrogen and oxygen gases produced on charge. Because the volumes of gas produced are not excessive (as with conventional flooded battery designs) they can be recombined to form water within the operating pressure of the SMF battery. Because the Microtex alloys produce so little gas, premature failure due to water loss is prevented. Hydrogen and oxygen gas are produced at the negative and positive electrodes respectively when water is broken down during charging. The simplified lead-acid battery reactions involving the negative oxygen and positive hydrogen ions produced when water is electrolyzed are:

 
  • Water decomposition on charge: H2O = 2H+ + O-
  • Gas evolution reaction on positive plate: 2O- – 2e = O2 Gas
  • Gas evolution reaction on negative plate: 2H+ + 2e = H2 Gas

From these simplified equations, it can be seen that the charged oxygen and hydrogen ions produced by the breakdown of water are in solution as ionic species. They are then attracted to the oppositely charged electrodes where (due to the electrochemistry of the charging process) hydrogen is reduced by gaining an electron and oxygen is oxidized by losing an electron. Because the gases are then trapped, water is lost from the electrolyte. However, the Tgel design efficiently contains these gases within the voids created in the immobilized electrolyte which now become small gas pockets. These pockets effectively store the gases which become reservoirs for subsequent recombination to form water.

Tubular Gel battery construction

Tubular Gel Batteries demand High quality materials of construction: In particular, the multitube gauntlet (PT Bags) used in the plate and the PVC separator are manufactured by Microtex to the most demanding specifications found in the lead-acid battery industry. This ensures a high burst pressure in the PT Bags gauntlet to resist cyclic volume changes of the active material. This volume change can lead to paste shedding and loss of capacity if lower grade materials with a lower burst strength PT Bags are used.

Likewise, Microtex’s Time Tested PVC separator has optimum porosity, low shrinkage and high stability in sulphuric acid. This ensures that the gel cell will meet its design criteria and guaranteed life, even under very arduous conditions.

No-compromise on the material specifications for bought-in components such as the pressure relief valve used to control the cell internal pressure. Unless the pressure relief valves have precisely the same opening pressures there could be water loss from some cells due to gases escaping. This causes imbalances between the individual cells of a tubular gel battery which leads to early failure. Use of the highest-quality components ensures that there is minimal cell to cell variation during a gel battery’s operation. Likewise, the connectors and containers use the best materials for the job and are supplied by certified manufacturers to Microtex’s demanding specifications. The Microtex designs, constructional materials and specifications for bought-in components are the result of decades of experience and closely working with and supporting their suppliers and customers. It is this dedicated and no-compromise approach to customer satisfaction that helps to set Microtex apart from their competitors.

 

Good balance of active materials within the TGel battery. The performance and life of any lead acid battery of any design are critically dependent on the amount of the three active materials: positive active material (PAM), negative active material (NAM) and the acid. In a fully charged lead acid battery, the PAM is lead dioxide and the NAM is spongy pure lead. These react together with the sulphuric acid electrolyte to form lead sulphate and water in the following battery reaction:

  • PbO2 + Pb + 2H2SO4 = 2PbSO4 + 2H2O
  • (PAM) (NAM) (ACID) (Discharged plates) (Water)

This is known as the double sulphate theory and it predicts the minimum amount of active materials required to provide the rated capacity of the battery. However, this is the real, not the theoretical world. In practice, the physical characteristics, quality of the materials and the quality of the manufacturing processes will also influence how much material is required and how long the battery will last in service. The PAM has a lower efficiency than the NAM and up to 20%, more may be needed to provide the same capacity as the negative material. Added to this is the utilization of the material, the higher the utilization the lower the life expectancy. To complicate matters the optimized balance changes when considering recombination gel batteries. Microtex, in association with international German and British experts, has optimized the materials and the manufacturing process to produce the best possible balance between the plate materials and acid content in its tubular gel battery.

 

It is fair to say that the performance and life expectancy of the Tgel battery is probably the envy of the rest of the lead acid battery industry. 

2v gel battery
2v Gel battery range
Comparion of standard properties of secondary batteries
Gel batteries are not the same!
PVC Battery Separators
PVC battery Separators for Tubular Gel Lead acid batteries

Other important aspects of a gel battery’s usefulness are its range and sizes. There are numerous applications mostly with different capacities, voltages and performance requirements. In addition to this, there are the containers or spaces where the batteries have to be fitted and in these instances, the skill of the person installing them is also an important consideration. In this respect Microtex has covered all the bases, the Microtex Tgel extensive range of 12v monobloc and 2V gel cells comes in a variety of sizes and capacities to meet stringent requirements of even Nuclear power stations.

The battery banks are fully insulated and designed to carry the high loads necessary for occasional or frequent high-rate discharges. The complete range of 2v OPzV battery provides for applications like telecom, solar, standby, switchgear and controls, power generating stations and substations, nuclear and thermal power stations, electricity transmission substations with reliable and durable backup power and energy storage. Made to order or standard size batteries in insulated steel containers are no problem for the Microtex technical and manufacturing teams. High-level technical assistance is available at no extra cost to help customers in designing the optimum and most cost-effective installation for their requirements. This includes designing and fitting zone 4 seismic racks and enclosures on customers’ premises.

The whole battery design can either use a standard-sized container or be a bespoke size to meet particular size and installation demand. Microtex will ensure that the customer receives the best advice for their requirement and budget. Again, working with the customer to give them the solutions they want, not the solutions a ‘supplier’ has; is the trademark of Microtex.

To this end, the importance of the right financial, as well as technical and engineering solution is recognised and placed at the centre of Microtex service.

Although the advantages of tubular GEL cells are substantial, their use is often restricted due to the higher cost when compared with standard flooded lead acid batteries. If the value for money is the main consideration, often described as Total Cost of Ownership (TCO) is more important than initial capital outlay, then the Tgel range is certainly the best option for you. The lack of maintenance cost and better charging efficiency can certainly save money, particularly when considering remote applications such as telecoms towers and diesel/solar hybrid generators. If we then factor in the higher cycle-life, which means you get more watt-hours through the battery when compared with lower cycle-life designs, the TCO is often lower for a TGel battery compared to a flooded option. In this way, any differences in capital outlay are more than compensated for by the net savings in both the operating and overall capital costs.

If you are considering purchasing batteries for any of the categories mentioned in this blog then you can be sure that you will get the best available advice from Microtex. Our dedicated technical team will ensure that you are guided through all the aspects to consider when making a purchase choice. The more we understand your requirements including financial aspects the better will be their advice. This means fewer problems for you our customer, with all the implications that bring to the partnership.

Microtex knows that our customers have customers and that your reputation can often depend on the quality of your supplier.

For this reason alone, Microtex has to be the first choice for any or all of your battery requirements.

Put your trust in the best battery, make it  Microtex.

Mike - CTO Microtex Energy

Share this article if you liked it, on

Share on facebook
Facebook
Share on twitter
Twitter
Share on reddit
Reddit
Share on linkedin
LinkedIn

Check out our complete range of batteries

Read more related articles

Why do batteries explode?

Why do lead-acid batteries explode?

During the end of charge all lead acid batteries produce hydrogen which is evolved by the breaking up of the electrolyte into hydrogen & oxygen. In sealed VRLA batteries either AGM batteries or Gel batteries, the gases are recombined inside the cell to form water.

Read More »
Mining locomotive battery

mining locomotive battery

The working environments of mines do differ depending on their location and the material being extracted. An underground coal mine for example will focus on fire abatement and protection against methane gas or lung diseases such as silicosis, whilst an open cast chalcopyrite mine would have different considerations.