TECHNICAL DATA - MICROTEX Traction Distribution Cells (Hard Rubber Container)
Cell Type |
Capacity in Ah at 27 °C 10Hr |
Overall |
Dimension |
in mm |
Cell (Appx.) |
Weight Kgs. |
Electrolyte Qty (Appx.) in Litres per cell |
Initial filling Electrolyte Specific Gravity |
Charging |
Current |
Cell center to center distance in mm |
||
L+5mm |
W+5mm |
H+10mm |
Without Electrolyte |
With Electrolyte |
Initial Charging rate(Amps) |
Initial No. of Hrs. Charging |
Normal Charging rate (Amps) |
Equalizing Charging rate (Amps) |
|||||
T 40H-LM |
40 |
98 |
165 |
255 |
4.75 |
7.20 |
2.00 |
1.205 |
4.00 |
50 |
5 |
1.20 |
117 |
T120H LM |
120 |
145 |
170 |
355 |
10.50 |
15.30 |
4.00 |
1.205 |
6.00 |
80 |
12 |
3.60 |
155 |
T 150H-LM |
150 |
260 |
184 |
355 |
15.00 |
24.00 |
7.50 |
1.205 |
7.50 |
70 |
15 |
4.50 |
197 |
T 200H-LM |
200 |
260 |
184 |
355 |
18.00 |
26.00 |
6.60 |
1.205 |
15.00 |
70 |
20 |
6.00 |
197 |
T250H LM |
250 |
260 |
208 |
390 |
26.00 |
38.50 |
10.50 |
1.205 |
12.50 |
80 |
25 |
7.50 |
235 |
T300H LM |
300 |
260 |
208 |
390 |
28.50 |
40.10 |
9.75 |
1.205 |
15.00 |
80 |
30 |
9.00 |
235 |
T320H LM |
320 |
260 |
208 |
390 |
28.50 |
40.10 |
9.75 |
1.205 |
16.00 |
80 |
32 |
10.00 |
235 |
T400H LM |
400 |
260 |
208 |
417 |
33.00 |
44.90 |
10.00 |
1.205 |
20.00 |
80 |
40 |
12.00 |
235 |
Note:
H-Height upto Terminal
All cells are supplied in dry uncharged condition
The electrical characteristics are nominal indicative value and can vary within +5.0%
In case of cells/batteries in Dry and Uncharged condition the initial filling and charging is to be carried out as per the parameters mentioned in Technical data sheet
H-Height upto Terminal
All cells are supplied in dry uncharged condition
The electrical characteristics are nominal indicative value and can vary within +5.0%
In case of cells/batteries in Dry and Uncharged condition the initial filling and charging is to be carried out as per the parameters mentioned in Technical data sheet
TECHNICAL DATA - MICROTEX Traction Distribution Cells (PPCP Container)
Cell Type |
Capacity in Ah at 27°C 10Hr |
Overall |
Dimension |
in mm |
Cell (Appx.) |
Weight Kgs. |
Electrolyte Qty (Appx.) in Litres per cell |
Initial filling Electrolyte Specific Gravity |
Charging |
Current |
Cell center to center distance in mm |
||
L +5mm |
W+5mm |
H+10mm |
Without Electrolyte |
With Electrolyte |
Initial Charging rate (Amps) |
Initial No. of Hrs. Charging |
Normal Charging rate (Amps) |
Equalizing Charging rate (Amps) |
|||||
T120P LM |
120 |
116 |
182 |
355 |
7.70 |
12.50 |
4.00 |
1.205 |
6.00 |
80 |
12 |
3.60 |
155 |
T 150P-LM |
150 |
260 |
169 |
345 |
10.65 |
19.70 |
7.50 |
1.205 |
7.50 |
70 |
15 |
4.50 |
182 |
T 200P-LM |
200 |
260 |
169 |
345 |
12.10 |
20.00 |
6.60 |
1.205 |
15.00 |
70 |
20 |
6.00 |
182 |
T250P LM |
250 |
260 |
169 |
520 |
15.90 |
28.50 |
10.50 |
1.205 |
12.50 |
80 |
25 |
7.50 |
182 |
T300P LM |
300 |
260 |
169 |
520 |
17.30 |
29.00 |
9.75 |
1.205 |
15.00 |
80 |
30 |
9.00 |
182 |
Note:
H - Height upto Terminal
All cells are supplied in dry uncharged condition
The electrical characteristics are nominal indicative value and can vary within+5.0%
In case of cells/batteries in Dry and Uncharged condition the initial filling and charging is to be carried out as per the parameters mentioned in Technical data sheet
H - Height upto Terminal
All cells are supplied in dry uncharged condition
The electrical characteristics are nominal indicative value and can vary within+5.0%
In case of cells/batteries in Dry and Uncharged condition the initial filling and charging is to be carried out as per the parameters mentioned in Technical data sheet
Talk to us . . .
Microtex Energy Private Limited.
42 & 43, 2nd Main, 2nd Phase,
Peenya Industrial Area,
Bengaluru - 560 058,
Karnataka, India
. . . Call Subodh to get a Quick quote
+91 9686 44 8899
or email us at info at microtex dot in
CIN No: U71220KA1977PTC003190 GSTN ID : 29AABCM1510D1Z2 © 2017 Microtex Energy Private Limited - All Rights Reserved